Immediate loading on mandibular edentulous patient with SFI Bar® overdenture

J Adv Prosthodont. 2011 Mar;3(1):47-50. doi: 10.4047/jap.2011.3.1.47. Epub 2011 Mar 31.

Abstract

Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar® (Cendres et Métaux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.

Keywords: Dental Implant; Immediate Loading; Overdenture; SFI-bar.

Publication types

  • Case Reports