Inhalation dose assessment of indoor radon progeny using biokinetic and dosimetric modeling and its application to Jordanian population

J Environ Radioact. 2011 Jun;102(6):574-80. doi: 10.1016/j.jenvrad.2011.03.003. Epub 2011 Apr 8.

Abstract

High indoor radon concentrations in Jordan result in internal exposures of the residents due to the inhalation of radon and its short-lived progeny. It is therefore important to quantify the annual effective dose and further the radiation risk to the radon exposure. This study describes the methodology and the biokinetic and dosimetric models used for calculation of the inhalation doses exposed to radon progeny. The regional depositions of aerosol particles in the human respiratory tract were firstly calculated. For the attached progeny, the activity median aerodynamic diameters of 50 nm, 230 nm and 2500 nm were chosen to represent the nucleation, accumulation and coarse modes of the aerosol particles, respectively. For the unattached progeny, the activity median thermodynamic diameter of 1 nm was chosen to represent the free progeny nuclide in the room air. The biokinetic models developed by the International Commission on Radiological Protection (ICRP) were used to calculate the nuclear transformations of radon progeny in the human body, and then the dosimetric model was applied to estimate the organ equivalent doses and the effective doses with the specific effective energies derived from the mathematical anthropomorphic phantoms. The dose conversion coefficient estimated in this study was 15 mSv WLM(-1) which was in the range of the values of 6-20 mSv WLM(-1) reported by other investigators. Implementing the average indoor radon concentration in Jordan, the annual effective doses were calculated to be 4.1 mSv y(-1) and 0.08 mSv y(-1) due to the inhalation of radon progeny and radon gas, respectively. The total annual effective dose estimated for Jordanian population was 4.2 mSv y(-1). This high annual effective dose calculated by the dosimetric approach using ICRP biokinetic and dosimetric models resulted in an increase of a factor of two in comparison to the value by epidemiological study. This phenomenon was presented by the ICRP in its new published statement on radon.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Administration, Inhalation
  • Air Pollutants, Radioactive / analysis
  • Air Pollutants, Radioactive / pharmacokinetics*
  • Air Pollution, Indoor / analysis
  • Environmental Exposure
  • Humans
  • Jordan
  • Kinetics
  • Models, Biological*
  • Radiation Dosage
  • Radiation Monitoring / methods*
  • Radon / analysis
  • Radon / pharmacokinetics*
  • Radon Daughters / analysis
  • Radon Daughters / pharmacokinetics*

Substances

  • Air Pollutants, Radioactive
  • Radon Daughters
  • Radon