In search of an optimal bedside screening program for arteriovenous fistula stenosis

Clin J Am Soc Nephrol. 2011 Apr;6(4):819-26. doi: 10.2215/CJN.06220710. Epub 2011 Mar 31.

Abstract

Background and objectives: Guidelines recommend systematically screening for stenosis using various methods, but no studies so far have compared all of the options. A prospective blinded study was performed to compare the performance of several bedside tests performed during dialysis in diagnosing angiographically proven >50% fistula stenosis.

Design, setting, participants, & measurements: In an unselected population of 119 hemodialysis patients with mature fistulas, physical examination (PE) was conducted; dynamic and derived static venous pressure (VAPR), blood pump flow/arterial pressure (Qb/AP) ratio, recirculation (R), and access blood flow (Qa) were measured; and angiography was performed.

Results: Angiography identified 59 stenotic fistulas: 43 stenoses were located upstream from the venous needle (inflow stenosis), 12 were located downstream (outflow stenosis), and 4 were located at both sites. The optimal tests for identifying an inflow stenosis were Qa < 650 ml/min and the combination of a positive PE "or" Qa < 650 ml/min (accuracy 80% and 81%, respectively), the latter being preferable because it was more sensitive (85% versus 65%, respectively) for a comparable specificity (79% versus 89%, respectively). The best tests for identifying outflow stenosis were PE and VAPR, with no difference between the two (accuracy 91% and 85%, sensitivity 75% and 81%, specificity 93% and 86%, respectively), the former being preferable because it was more reproducible, easier to perform, and applicable to all fistulas.

Conclusions: This study showed that fistula stenosis can be detected and located during dialysis with a moderate-to-excellent accuracy using PE and Qa measurement as screening procedures.

MeSH terms

  • Adult
  • Aged
  • Arteriovenous Shunt, Surgical / adverse effects*
  • Constriction, Pathologic
  • Female
  • Humans
  • Male
  • Middle Aged
  • Physical Examination
  • Prospective Studies
  • Renal Dialysis / adverse effects*
  • Vascular Patency*