[Microdrop-vitrification for epididymal spermatozoa without cryoprotectants]

Zhonghua Nan Ke Xue. 2010 Dec;16(12):1089-94.
[Article in Chinese]

Abstract

Objective: To explore the feasibility and safety of microdrop-vitrification for epididymal spermatozoa obtained by percutaneous epididymal sperm aspiration (PESA) without cryoprotectants.

Methods: We treated the epididymal sperm samples from 22 patients by conventional freezing (Group 1) and microdrop-vitrification without cryoprotectants (Group 2), and evaluated the effectiveness of the two methods by comparing their revival rate, retrieval rate and incidence of sperm nuclear DNA fractures.

Results: Motile sperm were found in all but 1 case in Group 1. The revival rates of the frozen sperm were low in both Groups 1 and 2 ([18.16 +/- 9.38]% vs [21.99 +/- 10.95]%, P > 0.05), but statistically significant differences were shown between the two groups in the retrieval rate ([58.39 +/- 12.67]% vs [70.82 +/- 14.94]%, P < 0.01). Before freezing, nuclear DNA fractures existed in the epididymal sperm samples of all the 22 patients, comet sperm were seen after unicellular gel electrophoresis, and the incidence of sperm nuclear DNA fracture was (26.68 +/- 9.45)%. After freezing, no increase was observed in the incidence of sperm nuclear DNA fracture in either Group 1 or 2 ([28.68 +/- 12.54]% vs [27.64 +/- 10.70]%, P > 0.05).

Conclusion: Microdrop can be used as a suitable freezing carrier for a low number of sperm, and cryoprotectant-free vitrification with microdrop may be a simple, safe and effective method for the cryopreservation of a low number of epididymal sperm.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Adult
  • Azoospermia / surgery*
  • Cryopreservation / methods*
  • Humans
  • Male
  • Spermatozoa*
  • Vitrification*