Introduction: Doppler transabdominal ultrasound is a validated screening test for chronic mesenteric ischaemia, but gas and obesity are limitations. Endoscopic ultrasound has been proposed as a comprehensive test to evaluate chronic upper abdominal pain and is capable of Doppler measurement. We aim to evaluate the accuracy of Doppler endoscopic ultrasound (D-EUS) as a single screening test to rule out chronic mesenteric ischaemia in patients with abdominal pain and compare it with Doppler transabdominal ultrasound (D-TUS).
Methods: We enrolled all patients ≥50 years with chronic upper abdominal pain and vascular risk referred for endoscopic ultrasound. All were scheduled for D-EUS and D-TUS plus a confirmatory test if one of the previous resulted positive. We estimated the accuracy of both techniques comparing them using McNemar test.
Results: 68 patients completed the study. Fifty-three (78%) underwent D-EUS, D-TUS, and a confirmatory test. Fifteen (38%) underwent follow-up after negative results. Three (4%) in the D-EUS group and 14 in the D-TUS (21%) were excluded due to artefacts. D-EUS presented a sensitivity of 63%, specificity of 84%, whilst D-TUS presented a sensitivity of 80% and a specificity of 78%. Specificity of D-EUS was not significantly different to D-TUS.
Conclusions: These results support the role of Doppler endoscopic ultrasound to exclude chronic mesenteric ischaemia as cause of chronic abdominal pain.
Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.