Penetration of the descending colon by a migrating intrauterine contraceptive device

J Korean Soc Coloproctol. 2010 Dec;26(6):433-6. doi: 10.3393/jksc.2010.26.6.433. Epub 2010 Dec 31.

Abstract

Foreign bodies in the gastrointestinal tract often cause serious complications, such as perforation, obstruction, abscess formation, or hemorrhage. This is a case in which a patient visited our hospital and complained of a vague lower abdominal pain that had been present for three months. She had an intrauterine device (IUD) inserted five years earlier. The abdominal X-ray, computed tomography and colonoscopy revealed that the IUD had penetrated into the descending colon. We tried to remove the IUD by colonoscopy but failed due to pain, so we removed the IUD surgically. Thus, we report a case in which a previously inserted IUD had penetrated into the descending colon and was surgically removed. We also present a brief review of the literature.

Keywords: Colon perforation; Foreign bodies; Intrauterine contraceptive device.

Publication types

  • Case Reports