Regional correlation of emphysematous changes in lung function and structure: a comparison between pulmonary function testing and hyperpolarized MRI metrics

J Appl Physiol (1985). 2011 Jan;110(1):225-35. doi: 10.1152/japplphysiol.00269.2010. Epub 2010 Sep 30.

Abstract

Regional and global relationships of lung function and structure were studied using hyperpolarized ³He MRI in a rat elastase-induced model of emphysema (n = 4) and healthy controls (n = 5). Fractional ventilation (r) and apparent diffusion coefficient (ADC) of ³He were measured at a submillimeter planar resolution in ventral, middle, and dorsal slices 6 mo after model induction. Pulmonary function testing (PFT) was performed before MRI to yield forced expiratory volume in 50 ms (FEV₅₀), airway resistance (R(I)), and dynamic compliance (C(dyn)). Cutoff threshold values of ventilation and diffusion, r* and ADC*, were computed corresponding to 80% population of pixels falling above or below each threshold value, respectively. For correlation analysis, r* was compared with FEV₅₀/functional residual capacity (FRC), R(I) and C(dyn), whereas ADC* was compared with FEV₅₀/FRC, total lung capacity (TLC), and C(dyn). Regional correlation of r and ADC was evaluated by dividing each of the three lung slices into four quadrants. C(dyn) was significantly larger in elastase rats (0.92 ± 0.16 vs. 0.61 ± 0.12 ml/cmH₂O). The difference of R(I) and FEV₅₀ was insignificant between the two groups. The r* of healthy rats was significantly larger than the elastase group (0.42 ± 0.03 vs. 0.28 ± 0.06), whereas ADC* was significantly smaller in healthy animals (0.27 ± 0.04 vs. 0.36 ± 0.01 cm²/s). No systematic difference in these quantities was observed between the three lung slices. A significant 33% increase in ADC* and a significant 31% decline in r* for elastase rats was observed compared with a significant 51% increase in C(dyn) and a nonsignificant 26% decline in FEV₅₀/FRC. Correlation of imaging and PFT metrics revealed that r and ADC divide the rats into two separate clusters in the sample space.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Animals
  • Contrast Media
  • Emphysema / diagnosis
  • Emphysema / pathology*
  • Emphysema / physiopathology*
  • Helium*
  • Isotopes
  • Lung / pathology*
  • Lung / physiopathology*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Radiopharmaceuticals
  • Rats
  • Rats, Sprague-Dawley
  • Reproducibility of Results
  • Respiratory Function Tests / methods*
  • Sensitivity and Specificity

Substances

  • Contrast Media
  • Isotopes
  • Radiopharmaceuticals
  • Helium