Sensor-augmented pump therapy from the diagnosis of childhood type 1 diabetes: results of the Paediatric Onset Study (ONSET) after 12 months of treatment

Diabetologia. 2010 Dec;53(12):2487-95. doi: 10.1007/s00125-010-1878-6. Epub 2010 Aug 14.

Abstract

Aims/hypothesis: The value of managing children with type 1 diabetes using a combination of insulin pump and continuous glucose monitoring starting from diagnosis for improving subsequent glycaemic control and preserving residual beta cell function was determined.

Methods: A total of 160 children (aged 1-16 years, mean ± SD: 8.7 ± 4.4 years; 47.5% girls) were randomised to receive insulin pump treatment with continuous glucose monitoring or conventional self-monitoring blood glucose measurements. The primary outcome was the level of HbA(1c) after 12 months. Other analyses included fasting C-peptide, glycaemic variability, sensor usage, adverse events, children's health-related quality of life and parent's wellbeing.

Results: HbA(1c) was not significantly different between the two groups, but patients with regular sensor use had lower values (mean 7.1%, 95% CI 6.8-7.4%) compared with the combined group with no or low sensor usage (mean 7.6%, 95% CI 7.3-7.9%; p=0.032). At 12 months, glycaemic variability was lower in the sensor group (mean amplitude of glycaemic excursions 80.2 ± 26.2 vs 92.0 ± 33.7; p=0.037). Higher C-peptide concentrations were seen in sensor-treated 12- to 16-year-old patients (0.25 ± 0.12 nmol/l) compared with those treated with insulin pump alone (0.19 ± 0.07 nmol/l; p=0.033). Severe hypoglycaemia was reported only in the group without sensors (four episodes).

Conclusion/interpretation: Sensor-augmented pump therapy starting from the diagnosis of type 1 diabetes can be associated with less decline in fasting C-peptide particularly in older children, although regular sensor use is a prerequisite for improved glycaemic control.

Trial registration: ISRCTN.org ISRCTN05450731

Funding: Medtronic International Trading Sàrl, Tolochenaz, Switzerland.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Age of Onset
  • Biosensing Techniques / instrumentation*
  • Biosensing Techniques / methods
  • Child
  • Child, Preschool
  • Diabetes Mellitus, Type 1 / diagnosis
  • Diabetes Mellitus, Type 1 / drug therapy*
  • Diabetes Mellitus, Type 1 / epidemiology
  • Female
  • Follow-Up Studies
  • Humans
  • Hypoglycemic Agents / administration & dosage
  • Hypoglycemic Agents / adverse effects
  • Infant
  • Insulin / administration & dosage*
  • Insulin / adverse effects
  • Insulin Infusion Systems* / adverse effects
  • Male
  • Quality of Life
  • Time Factors

Substances

  • Hypoglycemic Agents
  • Insulin

Associated data

  • ISRCTN/ISRCTN05450731