Autoantibodies to double-stranded DNA--intermethod comparison between four commercial immunoassays and a research biosensor-based device

Lupus. 2010 Jul;19(8):957-64. doi: 10.1177/0961203310369681.

Abstract

Patients with systemic lupus erythematosus (SLE) often develop a wide variety of serological manifestations including the presence of antibodies to double-stranded DNA (anti-dsDNA). Positivity for anti-dsDNA constitutes one of the laboratory criteria for the diagnosis of SLE and is therefore clinically relevant. We analyzed the diagnostic accuracies of four commercial anti-dsDNA immunoassays and compared the results with a recently established surface plasmon resonance (SPR) biosensor chip with covalently chip-immobilized dsDNA. The anti-dsDNA measurements were performed retrospectively in 50 patients with clinically proven SLE, 39 patients with other autoimmunopathies and 20 healthy controls. Data were evaluated by Receiver-Operator Characteristic (ROC) analysis, with special regard to SLE patients suffering from lupus nephritis. The ROC analyses for the four immunoassays and the SPR biosensor resulted in the following area-under-the-curve (AUC) and diagnostic efficiency (DE) values in descending order: Bindazyme AUC, 0.89; DE, 0.88; ELiA AUC, 0.89; DE, 0.86; SPR biosensor AUC, 0.82; DE, 0.80; Farrzyme AUC, 0.77; DE, 0.77; Farr AUC, 0.77; DE, 0.70. When considering the 22 nephritis SLE patients the following AUC were observed: Bindazyme 0.98; EliA 0.95; SPR biosensor 0.93; Farr 0.89; Farrzyme 0.88. Although various methodologies for the determination of anti-dsDNA were compared, the overall diagnostic accuracy was found satisfactory in all immunoassays. Best data were found for the Bindazyme assay. We referenced the measurements to our in-house SPR biosensor device which showed good AUC and DE values. When optimized, this technique, allowing to monitor antigen/ antibody interactions in real-time, may add a new analytical quality to the existing methods, potentially beneficial in diagnosis and clinical monitoring of SLE.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Antibodies, Antinuclear / immunology*
  • Autoantibodies / immunology*
  • Biosensing Techniques*
  • DNA / immunology*
  • Humans
  • Immunoassay / instrumentation*
  • Immunoassay / methods*
  • Lupus Erythematosus, Systemic / diagnosis
  • Lupus Erythematosus, Systemic / immunology
  • ROC Curve
  • Sensitivity and Specificity
  • Surface Plasmon Resonance / instrumentation
  • Surface Plasmon Resonance / methods

Substances

  • Antibodies, Antinuclear
  • Autoantibodies
  • DNA