Pulsed-gradient spin-echo monitoring of restricted diffusion in multilayered structures

J Magn Reson. 2010 Aug;205(2):181-95. doi: 10.1016/j.jmr.2010.04.017. Epub 2010 May 31.

Abstract

A general mathematical basis is developed for computation of the pulsed-gradient spin-echo signal attenuated due to restricted diffusion in multilayered structures (e.g., multiple slabs, cylindrical or spherical shells). Individual layers are characterized by (different) diffusion coefficients and relaxation times, while boundaries between adjacent layers are characterized by (different) permeabilities. Arbitrary temporal profile of the applied magnetic field can be incorporated. The signal is represented in a compact matrix form and the explicit analytical formulas for the elements of the underlying matrices are derived. The implemented algorithm is faster and much more accurate than classical techniques such as Monte Carlo simulations or numerical resolutions of the Bloch-Torrey equation. The algorithm can be applied for studying restricted diffusion in biological systems which exhibit a multilayered structure such as composite tissues, axons and living cells.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Diffusion Magnetic Resonance Imaging / methods*
  • Echo-Planar Imaging / methods*
  • Electromagnetic Fields
  • Extracellular Space
  • Models, Statistical
  • Permeability