Coherent 2 microm differential absorption and wind lidar with conductively cooled laser and two-axis scanning device

Appl Opt. 2010 Apr 1;49(10):1809-17. doi: 10.1364/AO.49.001809.

Abstract

A coherent 2 microm differential absorption and wind lidar (Co2DiaWiL) was developed to measure CO(2) concentration and line-of-sight wind speed. We conductively cooled a pumping laser head to -80 degrees C and diode arrays to approximately 20 degrees C. A Q-switched laser outputs an energy of 80 mJ (pulse width 150 ns (FWHM), pulse repetition frequency up to 30 Hz). CO(2) measurements made over a column range (487-1986 m) for 5 min accumulation time pairs achieved 0.7% precision. Line-of-sight wind speeds for ranges up to approximately 20 km and returns from a mountainside located 24 km away from the Co2DiaWiL were obtained.