Monoaxial versus polyaxial screw insertion in angular stable plate fixation of proximal humeral fractures: radiographic analysis of a prospective randomized study

J Trauma. 2010 Dec;69(6):1545-51. doi: 10.1097/TA.0b013e3181c9b8a7.

Abstract

Background: Monoaxial and polyaxial screw insertion are used in angular stable plating of displaced proximal humeral fractures. Aim of the study was to compare both fixation techniques by radiographic evaluation.

Methods: Prospective randomized treatment with monoaxial or polyaxial screw insertion in angular stable anatomic preshaped plates of displaced proximal humeral fractures. Analysis of standardized true anterior-posterior (true a.p.) and outlet-view radiographs at 1 day, 6 weeks, 3 months, and 6 months after surgery by two radiologists with respect to radiographic evidence of secondary varus displacement, cut out of screws, osteonecrosis, and hardware failure. Secondary varus displacement was defined as a varus decrease of the humeral head-shaft angle of > 10 degree in true a.p. radiographs.

Results: Sixty-six consecutive patients (48 women, [72.7%]; 18 men, [27.3%]; mean age 67.7 years [95% CI, 63.9-71.6]) with displaced proximal humeral fractures were evaluated in this study. Nineteen patients (29%) showed secondary varus displacement of > 10-degree angle. In 6 cases (9%), intra-articular cut out of screws was found. Furthermore, 1 case (2%) of nonunion was observed. No relationship between monoaxial and polyaxial screw insertion was found regarding occurrence of secondary varus displacement (monoaxial, 11/polyaxial, 8; p = 0.91) or screw cut out (monoaxial, 4/polyaxial, 2; p = 0.64). Prevalence of secondary varus displacement and hardware cut out was related to patients age (p = 0.02) and fracture pattern, according to Neer- and AO/OTA-classification (p < 0.001). The average immediate postoperative head-shaft angle was 135.2 degrees (CI, 132.3-138.1) in the group without radiographic complication, compared with 126.7-degree angle (CI, 123.6-129.7) among those with secondary varus displacement of > 10-degree angle and screw cut out (p < 0.001). Furthermore, in cases of an immediate postoperative head-shaft angle of < 130 degrees, there was a 48% incidence of secondary varus dislocation (n = 13) versus 15% in cases with a head-shaft angle > 130 degrees (n = 6, p = 0.004).

Conclusion: Monoaxial and polyaxial screw insertion allow for mechanical stabilization in angular stable plating of unstable proximal humerus fractures. Radiographic evidence of secondary varus displacement of > 10-degree angle and screw cut out was seen similarly often in both fixation techniques. To avoid secondary varus displacement and screw cut out, restoration of a humeral head-shaft angle of > 130 degrees seems to be important in monoaxial and polyaxial fixation of proximal humeral fractures.

Publication types

  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Bone Plates*
  • Chi-Square Distribution
  • Female
  • Fracture Fixation, Internal / instrumentation
  • Fracture Fixation, Internal / methods*
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications
  • Prospective Studies
  • Radiography
  • Shoulder Fractures / diagnostic imaging*
  • Shoulder Fractures / surgery*
  • Statistics, Nonparametric
  • Treatment Outcome