Salvage treatment for venous aneurysm complicating vascular access arteriovenous fistula: use of an exoprosthesis to reinforce the vein after aneurysmorrhaphy

Eur J Vasc Endovasc Surg. 2010 Jul;40(1):100-6. doi: 10.1016/j.ejvs.2010.01.021. Epub 2010 Mar 3.

Abstract

Objectives: We report a new salvage technique for treating venous aneurysms (VAs) complicating vascular access arteriovenous fistula (AVF) using externally reinforced venous aneurysmorrhaphy.

Design: A retrospective study over a 20-month period from a single centre.

Patients: Patients presenting to the vascular surgery department, Bordeaux University Hospital for revision of a vascular access AVF were included.

Methods: Reinforced venous aneurysmorrhaphy consisted in removal of redundant vessel wall followed by reinforcement using an external prosthetic graft. Patency, diameter and flow were assessed by duplex ultrasound at 1, 6 and 12 months after salvage.

Results: Thirty-eight eligible patients were identified. Five were excluded because VA was associated with central vein stenosis; the remaining 33 underwent salvage. Indications were rapidly expanding or painful VA in seven cases; VA with frequent bleeding or damaged overlying skin in eight; VA in close relation to a stenosis in two; and VA associated with high-flow rate in 16. Cannulation was attempted after 30 days. Mean follow-up time was 12 S.D. 5 months (range: 4-22). Two repaired AVFs failed. Primary 1-year patency was 93%. No aneurysm or infection occurred. Reduction of high flow was successful in 12 of 16 patients. The remaining four required re-operation.

Conclusions: Reinforced venous aneurysmorrhaphy is effective in controlling venous dilation and achieving patency. Reduction of high-flow rates was not always achieved. Further study is needed to evaluate long-term efficacy of this treatment.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Aneurysm / diagnostic imaging
  • Aneurysm / etiology
  • Aneurysm / physiopathology
  • Aneurysm / surgery*
  • Arteriovenous Shunt, Surgical / adverse effects*
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis*
  • Female
  • France
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Prosthesis Design
  • Regional Blood Flow
  • Renal Dialysis*
  • Reoperation
  • Retrospective Studies
  • Salvage Therapy
  • Time Factors
  • Treatment Outcome
  • Ultrasonography, Doppler, Duplex
  • Upper Extremity / blood supply*
  • Vascular Patency
  • Veins / surgery
  • Young Adult