Improved quantification and normal limits for myocardial perfusion stress-rest change

J Nucl Med. 2010 Feb;51(2):204-9. doi: 10.2967/jnumed.109.067736.

Abstract

We aimed to improve the quantification of myocardial perfusion stress-rest changes in myocardial perfusion SPECT (MPS) studies for the optimal automatic detection of ischemia and coronary artery disease (CAD).

Methods: Rest-stress (99m)Tc MPS studies (997 cases; 651 consecutive cases with correlating angiography and 346 cases with less than 5% likelihood (low likelihood [LLK]) of CAD) were analyzed. Normal limits for stress-rest changes were derived from additional LLK patients (40 women, 40 men). We computed the global stress-rest change (C-SR) by integrating direct stress-rest changes for each polar map pixel. Additionally, stress-rest change and total perfusion deficit (TPD) at stress were combined in 1 variable (C-TPD) for the optimal detection of CAD.

Results: The area under the receiver-operating-characteristic curve (AUC) for C-SR (0.92) was larger than that for stress TPD-rest TPD (0.88) for the identification of stenosis of 70% or more (P < 0.0001). AUC (0.94) and sensitivity (90%) for C-TPD were higher than those for stress TPD (0.91 and 83%, respectively) (P < 0.0001), whereas specificity remained the same (81%).

Conclusion: C-SR and C-TPD provide higher diagnostic performance than difference between stress and rest TPD or stress hypoperfusion analysis.

Publication types

  • Research Support, N.I.H., Extramural
  • Validation Study

MeSH terms

  • Adult
  • Aged
  • Algorithms
  • Coronary Angiography
  • Coronary Artery Disease / diagnostic imaging*
  • Exercise Test / statistics & numerical data*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Myocardial Perfusion Imaging / statistics & numerical data*
  • Radiopharmaceuticals
  • Reference Values
  • Retrospective Studies
  • Technetium Tc 99m Sestamibi
  • Tomography, Emission-Computed, Single-Photon / statistics & numerical data*

Substances

  • Radiopharmaceuticals
  • Technetium Tc 99m Sestamibi