[Dynamics of a vortex with the U-shaped filament in the heart of a ground squirrel]

Biofizika. 2009 Nov-Dec;54(6):1088-102.
[Article in Russian]

Abstract

The dynamics of an electrical scroll wave with the U-shaped filament with both ends of the filament being "anchored" on the endocardial surface and the dependence of the structure of pseudoECG on the dynamics of the vortex during the development of polymorphic tachysystolia have been studied by applying premature stimuli to the "target phase" with subsequent registration of the spatial and temporal distribution of electrical potential throughout the surface (endocardial and epicardial) of a thin (approximately 1 mm) preparation. It was found that (1) the psedoECG of the polymorphic form during the tachysystolia attack can be observed in the case that the position of the filament ends on the surfaces of the preparation does not practically change from turn to turn (filament ends are "anchored"); (2) the thread of a scroll wave during this attack can twist and untwin (twisted filament), just as it was the case for scroll waves with a straight filament; (3) in the case of pseudoECG of polymorphic form, the twisting and untwining of the filament were stronger (the angle of maximal twisting was 120 degrees and more), and the angle of twisting changed by a substantially greater value from turn to turn as compared with the pseudoECG of monomorphic form; (4) in the case of pseudoECG of polymorphic form, the time interval between the appearance of waves on the surfaces of the preparation (Tepi-endo) was substantially greater and changed to a greater extent from turn to turn of the vortex; and (5) simultaneously with the appearance of pseudoECG of polymorphic form and the onset of changes in the twisting of the scroll and the Tepi-endo interval indicated in (2-4), significant changes in the patterns of coverage of the surface by excitation occurred. Based on the results obtained, an explanation of the reasons for the appearance of excitation breakdown patterns on the surface of the myocardium was proposed, which differs from the traditional viewpoint. These patterns may be the result of reflection on myocardial surfaces of the activity of not different simultaneously occurring sources of initiation of excitation but of a single three-dimensional vortex whose filament twists when passing through the thickness of the myocardium and can closely approach one or the other surface.

Publication types

  • English Abstract
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Electrocardiography
  • Endocardium / physiopathology
  • Heart / physiopathology*
  • Heart Conduction System / physiopathology*
  • In Vitro Techniques
  • Pericardium / physiopathology
  • Sciuridae
  • Tachycardia / physiopathology*