Diagnostic assessment to estimate and minimize neutron dose rates received by occupationally exposed individuals at cyclotron facilities

Appl Radiat Isot. 2010 Mar;68(3):489-95. doi: 10.1016/j.apradiso.2009.12.002. Epub 2009 Dec 21.

Abstract

Since 2003, radiopharmaceuticals for medical diagnostic purposes have been produced at the Instituto de Engenharia Nuclear, in Brazil, using two cyclotron accelerators - CV-28 and RDS111. As a result of the ever increasing production, a diagnostic assessment to reduce neutron dose rates received by occupationally exposed individuals during irradiation processes has been developed. The purpose of this work is to present this assessment, which is currently being applied to both the Fluorine and Iodine targets of CV-28 and RDS111 cyclotron accelerators.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cesium Radioisotopes / analysis*
  • Cyclotrons*
  • Fluorine Radioisotopes / analysis*
  • Humans
  • Neutron Activation Analysis
  • Neutrons*
  • Occupational Exposure / analysis*
  • Radiation Dosage
  • Radiopharmaceuticals / chemical synthesis
  • Radiopharmaceuticals / chemistry*

Substances

  • Cesium Radioisotopes
  • Fluorine Radioisotopes
  • Radiopharmaceuticals