Chest computed tomography (CT) immediately after CT-guided transthoracic needle aspiration biopsy as a predictor of overt pneumothorax

Korean J Intern Med. 2009 Dec;24(4):343-9. doi: 10.3904/kjim.2009.24.4.343. Epub 2009 Nov 27.

Abstract

Background/aims: This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation.

Methods: Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients.

Results: Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax.

Conclusions: CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax.

Keywords: Biopsy, needle; Pneumothorax; Risk factors; Tomography, X-ray computed.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Biopsy, Needle / adverse effects*
  • Female
  • Humans
  • Incidence
  • Male
  • Middle Aged
  • Pneumothorax / diagnostic imaging*
  • Pneumothorax / epidemiology
  • Radiography, Thoracic / methods*
  • Retrospective Studies
  • Thorax / pathology*
  • Tomography, X-Ray Computed / methods*