Determination of benzalkonium chloride in viscous ophthalmic drops of azithromycin by high-performance liquid chromatography

J Zhejiang Univ Sci B. 2009 Dec;10(12):877-82. doi: 10.1631/jzus.B0920229.

Abstract

A high-performance liquid chromatography (HPLC) system was used in the reversed phase mode for the determination of benzalkonium chloride (BKC) in azithromycin viscous ophthalmic drops. A Venusil-XBP(L)-C(18) (150 mmx4.6 mm, 5 microm) column was used at 50 degrees C. The mobile phase consisted of a mixture of methanol-potassium phosphate (16:5, v/v). Two sample preparation methods were compared. The results suggested that, compared with an extraction procedure, a deproteinization procedure was much quicker and more convenient. Using the deproteinization procedure for sample preparation, calibration curves were linear in the range 5.0 to approximately 50 microg/ml. The within-day and inter-day coefficients of variation were less than 10%. The average recoveries were determined as 96.70%, 98.52%, and 97.96% at concentrations of 10.0, 30.0, and 50.0 microg/ml, respectively. Variability in precision did not exceed 5%. In conclusion, this HPLC method using a simple sample treatment procedure appears suitable for monitoring BKC content in azithromycin viscous ophthalmic drops.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Azithromycin / analysis*
  • Benzalkonium Compounds / chemistry*
  • Calibration
  • Chemistry Techniques, Analytical / methods*
  • Chromatography / methods
  • Chromatography, High Pressure Liquid / methods*
  • Models, Chemical
  • Ophthalmic Solutions / chemistry*
  • Reproducibility of Results
  • Viscosity

Substances

  • Benzalkonium Compounds
  • Ophthalmic Solutions
  • Azithromycin