Assessment of respiratory mechanical properties with constant-phase models in healthy and COPD lungs

Comput Methods Programs Biomed. 2010 Jan;97(1):78-85. doi: 10.1016/j.cmpb.2009.06.006. Epub 2009 Jul 22.

Abstract

This study employs the concept of applying constant-phase models to input respiratory impedance data obtained with the non-invasive Forced Oscillation Technique (FOT) lung function test. Changes in respiratory mechanics from healthy and chronic obstructive pulmonary disease (COPD) diagnosed patients are observed with a four- and a five-parameter constant-phase model. Tissue damping (p<<0.01), tissue elastance (p<0.02) and tissue hysteresivity (p<<0.01) are calculated from the identified model parameters, providing significant separation between healthy and COPD groups. Limitations of the four-parameter constant-phase model are shown in relation to frequency-dependent impedance values within the range 4-48 Hz. The results clearly show that the five-parameter constant-phase model outperforms the four-parameter constant-phase model in this frequency range. The averaged error is 0.02 and 0.04 for healthy subjects in the five-parameter and four-parameter constant-phase models, respectively. The results show that the identified model values are sensitive to variations between healthy and COPD lungs.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Airway Resistance
  • Analysis of Variance
  • Confidence Intervals
  • Elasticity
  • Humans
  • Lung / physiology*
  • Middle Aged
  • Models, Biological*
  • Plethysmography, Impedance
  • Pulmonary Disease, Chronic Obstructive / diagnosis*
  • Pulmonary Disease, Chronic Obstructive / physiopathology*
  • Respiratory Mechanics / physiology*
  • Spirometry
  • Statistics, Nonparametric