Simultaneous measurements of radon and thoron exhalation rates and comparison with values calculated by UNSCEAR equation

J Radiat Res. 2009 Jul;50(4):333-43. doi: 10.1269/jrr.08121. Epub 2009 Jun 9.

Abstract

We simultaneously measured radon and thoron exhalation rates in areas of weathered acid rocks in Japan to investigate the relationship between them and between measured and calculated radon exhalation rates. To calculate the radon exhalation rate, we used an equation proposed by UNSCEAR. Our analysis showed that both the radon and thoron exhalation rates measured at one location in a natural environment fluctuated widely, even within one day. We found a strong correlation between the radon and thoron exhalation rates. The measured radon exhalation rates tended to be lower than the calculated values: the mean ratio of the measured exhalation rate to the calculated rate was 0.65. We concluded that the UNSCEAR equation is applicable under a controlled environment (temperature, humidity, etc.), but not where there are artificial underground structures that may influence the transportation of radon in soil.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Air Pollutants, Radioactive / analysis*
  • Algorithms*
  • Radiation Monitoring / methods*
  • Radon / analysis*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Soil Pollutants, Radioactive / analysis*

Substances

  • Air Pollutants, Radioactive
  • Soil Pollutants, Radioactive
  • Radon