Comment on "The effect of evaporation on the wicking of liquids into a metallic weave" by N. Fries, K. Odic, M. Conrath and M. Dreyer

J Colloid Interface Sci. 2009 Aug 1;336(1):374-5. doi: 10.1016/j.jcis.2009.04.006. Epub 2009 Apr 12.

Abstract

A recent paper reported capillary rise and evaporation experiments in metallic wicks, as well as a mathematical model. The authors found a consistent discrepancy between the model predictions and data: The model over-predicted the capillary height rise by about 20%. The model used assumes that the porous medium is either fully wet or dry, an assumption that is particularly unsuited to evaporation from the wick surface. An alternative variable-saturation model is proposed that provides a possible explanation for the 20% discrepancy reported by the authors.

Publication types

  • Comment