Tibial fixation in anterior cruciate ligament reconstruction with bone-patellar tendon-bone and semitendinosus-gracilis autografts: a comparison between bioabsorbable screws and bioabsorbable cross-pin fixation

Am J Sports Med. 2009 Apr;37(4):808-12. doi: 10.1177/0363546508328413. Epub 2009 Feb 13.

Abstract

Background: Knee instability after anterior cruciate ligament reconstruction rarely manifests with activities of daily living, but it may occur in high-level sports performance, resulting in secondary injuries. Faced with these circumstances, sports orthopaedists have continued to improve on the results obtained with surgical techniques for treating knee joint injuries.

Hypothesis: Transverse tibial fixation with bioabsorbable cross pins is a valid technique for anterior cruciate ligament reconstruction with both the patellar tendon (bone-patellar tendon-bone) and semitendinosus and gracilis tendon.

Study design: Cohort study; Level of evidence, 3.

Methods: The study population was 120 patients operated on by the same surgeon and subdivided into 4 subgroups of 30 subjects each. Patients were chosen and assigned to each group consecutively. Patients in group 1 (bone-patellar tendon-bone) were implanted with bioabsorbable interference screws, group 2 (bone-patellar tendon-bone) received 2 bioabsorbable cross pins, group 3 (semitendinosus and gracilis tendon) received a bioabsorbable interference screw, and group 4 (semitendinosus and gracilis tendon) received 2 bioabsorbable cross pins. Patients were assessed at 5-year follow-up for International Knee Documentation Committee Knee Ligament Standard Evaluation Form, Lysholm Knee Scoring Scale, Lysholm-Tegner Activity Scale, and KT-1000 arthrometer testing.

Results: The results at 5 years after anterior cruciate ligament reconstruction were similar across all 4 groups. No significant differences have been observed between groups.

Conclusion: The results suggest that transverse tibial fixation with bioabsorbable cross pins is a safe and reliable procedure, yielding clinical results that are comparable with those of the more widely used bioabsorbable interference screws.

Publication types

  • Comparative Study

MeSH terms

  • Absorbable Implants*
  • Adolescent
  • Adult
  • Anterior Cruciate Ligament / surgery
  • Arthroplasty / instrumentation*
  • Arthroplasty / methods
  • Bone Nails*
  • Bone Screws*
  • Bone-Patellar Tendon-Bone Grafting / instrumentation*
  • Cohort Studies
  • Female
  • Humans
  • Male
  • Middle Aged
  • Tibia / surgery*
  • Transplantation, Autologous