Fenestrated endovascular repair for juxtarenal aortic pathology

J Vasc Surg. 2009 Mar;49(3):568-74; discussion 574-5. doi: 10.1016/j.jvs.2008.10.022. Epub 2009 Jan 9.

Abstract

Objective: To evaluate the outcomes after fenestrated endovascular aortic repair (f-EVAR) in a tertiary European referral center.

Methods: All patients treated with commercially available custom-made f-EVAR between September 2002 and June 2007 were prospectively enrolled in a computerized database including co-morbidities and aneurysm morphology. Patients were retrospectively analyzed. Follow-up consisted of clinical examinations and computed tomography (CT) scanning.

Results: A total of 54 patients were included in this study. Median age was 72 (interquartile range [IQR] 68-76) years and 85% were men. Median preoperative aneurysm diameter was 60 (53-66) mm. One hundred thirty-four vessels were targeted (43 scallops, 91 fenestrations) and 96 stents were placed (69 bare, 27 covered). Target vessel catheterization was achieved in 98% of cases. Two patients (3.7%) died within 30 days, 1 from trash embolization and multiorgan failure and 1 from retroperitoneal bleeding caused by a renal artery perforation. Three type I endoleaks occurred intraoperatively, two sealed pre-discharge and one was treated with a Palmaz stent (Cordis, Miami Lakes, Fla) on postoperative day 4. Thirteen patients had type II endoleaks, and 2 required treatment. The median clinical follow-up was 25 (12-32) months with median CT follow-up of 22 (4-26) months. Aneurysm diameter decreased >or=5 mm in 47%, was unchanged in 50%, and increased >or=5 mm in 3% of patients at 1 year. There were three type II endoleaks at 1-year follow-up, one of which was successfully treated after 19 months due to aneurysm growth. Ninety-six percent of target vessels remained patent during the study period and all occlusions occurred within the first year of follow-up. Five target vessels occluded (2 renal arteries [RAs] and 3 superior mesenteric arteries [SMAs]) without symptoms during follow-up and successful reinterventions were done on 2 stenosed RAs. Three patients suffered creatinine increase but none needed dialysis. One late aneurysm-related death occurred due to massive bleeding during redo surgery for infection.

Conclusion: Despite complex anatomy or severe comorbidities in these patients f-EVAR has acceptable short- and midterm results in this series which includes a learning curve and offers a valid treatment alternative to patients unsuitable for standard EVAR or open repair.

MeSH terms

  • Aged
  • Aortic Aneurysm / complications
  • Aortic Aneurysm / diagnostic imaging
  • Aortic Aneurysm / mortality
  • Aortic Aneurysm / surgery*
  • Aortography / methods
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis Implantation / mortality
  • Blood Vessel Prosthesis*
  • Databases as Topic
  • Europe
  • Female
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Prosthesis Design*
  • Prosthesis Failure
  • Reoperation
  • Retrospective Studies
  • Stents*
  • Time Factors
  • Tomography, Spiral Computed
  • Treatment Outcome
  • Vascular Patency