Troublesome occipital neuralgia developed by c1-c2 harms construct

J Korean Neurosurg Soc. 2008 Feb;43(2):111-3. doi: 10.3340/jkns.2008.43.2.111. Epub 2008 Feb 20.

Abstract

Recently, Harms and Melcher modified Goel's approach, the C1 lateral mass and C2 pedicle screw fixation, and the new technique is currently in favor among neurosurgeons. Comparing to the advantages of Harms construct, the disadvantages were not extensively investigated. We experienced a patient with severe occipital pain developed after the C1 lateral mass screw placement for the traumatic atlantoaxial instability. We reviewed literatures about Harms construct with focus on the occipital neuralgia as a postoperative complication and suggest here technical tips to avoid the troublesome pain.

Keywords: Atlantoaxial instability; Lateral mass screw; Occipital neuralgia.

Publication types

  • Case Reports