Chloride determination by ion chromatography in petroleum coke after digestion by microwave-induced combustion

J Chromatogr A. 2008 Dec 12;1213(2):249-52. doi: 10.1016/j.chroma.2008.10.079. Epub 2008 Oct 25.

Abstract

Microwave-induced combustion was applied to petroleum coke digestion in closed vessels for further chloride determination by ion chromatography. Samples were pressed as pellets and placed on a quartz holder. Combustion was performed using oxygen pressure of 2 MPa and 50 microl of 6 moll(-1) NH(4)NO(3) as aid for ignition. Recoveries from 97 to 102% were obtained for all studied absorbing solutions (water, H(2)O(2), Na(2)CO(3) or (NH(4))(2)CO(3)). Accuracy was evaluated using certified reference materials with agreement better than 98% using water as absorbing solution with reflux step. The limit of quantification was 3.8 microg g(-1).

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Chlorides / analysis*
  • Coke / analysis*
  • Microwaves
  • Petroleum / analysis

Substances

  • Chlorides
  • Coke
  • Petroleum