This paper describes a newly devised autosomal short tandem repeat (STR) multiplex polymerase chain reaction (PCR) systems for 10 loci (D1S1656, D2S1353, D8S1132, D12S1090, D14S608, D18S535, D19S253, D20S480, D21S226, and D22S689) unlinked to the core STR loci (non-CODIS loci). Of 252 samples taken from the Japanese population, PCR products ranged in length from 107 bp to 319 bp. No significant deviations from Hardy-Weinberg equilibrium were observed at any of the 10 loci. The accumulated power of discrimination and power of exclusion for the 10 loci were 0.999999999998 and 0.99991, respectively. We conclude that the present multiplex system for the 10 non-CODIS loci represents a powerful tool for forensic applications.