Myocardial strain in sub-acute peri-infarct myocardium

Int J Cardiovasc Imaging. 2009 Feb;25(2):151-9. doi: 10.1007/s10554-008-9364-7. Epub 2008 Oct 15.

Abstract

Purpose: In the absence of additional ischemic insults, the peri-infarct region surrounding the infarct myocardium can recover function. T2 weighted MRI signal is sensitive to edema and used to detect peri-infarct, salvageable myocardium. The main purpose of this study was to investigate the alterations in myocardial strain in the peri-infarct myocardium as compared to normal and infarct myocardium.

Materials and methods: Comprehensive MRI of the myocardium was performed in five pigs 6-7 days following coronary artery occlusion-reperfusion myocardial injury. MRI included tagged cine images for myocardial strain, T2weighted (T2w)-images and late gadolinium enhancement (LGE) for assessing myocardial viability. Automated signal intensity thresholds were used to define tissue edema and myocardial infarct. Maximum-shortening strains were analyzed in the infarct, peri-infarct and normal myocardial sectors. The results were correlated with triphenyltetrazolium-chloride (TTC) and hemotoxylin-eosin stained tissue images.

Results: We found an excellent correlation of LGE with TTC (r = 0.94, P < 0.05). T2w-images markedly overestimated the infarct size (25 +/- 3%). Both the healthy and peri-infarct myocardial sectors had higher myocardial strain than infarct myocardial sectors (P < 0.05). Clear demarcation between infarct and non-infarct myocardium was noted on histology.

Conclusion: Peri-infarct myocardium continues to demonstrate T2 signal enhancement to at least 7 days, but this region has preserved mechanical function. T2-weighted imaging and myocardial strain measurements provide complementary information and both may be useful for characterization of the peri-infarct myocardium.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Animals
  • Contrast Media / administration & dosage
  • Gadolinium DTPA / administration & dosage
  • Image Processing, Computer-Assisted
  • Linear Models
  • Magnetic Resonance Imaging, Cine / methods*
  • Myocardial Infarction / physiopathology*
  • Myocardium / pathology
  • Swine

Substances

  • Contrast Media
  • Gadolinium DTPA