Development of PLS calibration models from UV-Vis spectra for TOC estimation at the outlet of a fuel park wastewater treatment plant

Environ Technol. 2008 Aug;29(8):891-8. doi: 10.1080/09593330802015581.

Abstract

In the present work ultraviolet (UV)-visible spectra of water samples collected at the outlet of a fuel park wastewater treatment plant, including biological treatment, were acquired and used for the development of partial least squares (PLS) calibration models for the fast and simple estimation of total organic carbon (TOC). Three different PLS models were developed and compared on the basis of a common spectral range. The first model was obtained using spectra of raw samples, the second using spectra of diluted samples, to assess signal saturation in the UV region, and the third using spectra of both diluted and raw samples, in order to expand the narrow interval of TOC concentration values present in the original dataset. The root mean squared error of cross-validation values for the developed PLS models were 2.3, 1.0 and 4.4 mg Cl(-1), respectively, and the validation results where highly satisfactory (root mean squared error of prediction values of 1.8, 0.8 and 4.5 mg Cl(-1), respectively).

Publication types

  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Calibration
  • Environmental Monitoring / methods*
  • Industrial Waste / analysis*
  • Least-Squares Analysis
  • Organic Chemicals / analysis*
  • Spectrophotometry, Ultraviolet
  • Water Pollutants, Chemical / analysis*

Substances

  • Industrial Waste
  • Organic Chemicals
  • Water Pollutants, Chemical