A new monitor for routine thermal and epithermal neutron fluence rate monitoring in k0 INAA

Appl Radiat Isot. 2008 Dec;66(12):1964-9. doi: 10.1016/j.apradiso.2008.06.001. Epub 2008 Jun 7.

Abstract

The Zr-Au set for monitoring the thermal and epithermal neutron fluence rate and the epithermal spectrum parameter alpha is not always practicable for routine application of INAA in well-thermalized facilities. An alternative set consisting of Cr, Au and Mo provides values for the thermal neutron fluence rate, f and alpha that are not significantly different from those found via the Zr-Au method and the Cd-covered Zr-method. The IRMM standard SMELS-II was analyzed using the (Au-Cr-Mo) monitor and a good agreement was obtained.

MeSH terms

  • Equipment Design
  • Equipment Failure Analysis
  • Neutron Activation Analysis / instrumentation*
  • Neutron Activation Analysis / methods
  • Radiation Dosage
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Thermography / instrumentation*
  • Thermography / methods