Abstract
We describe a case of a 46-year-old woman with dehiscence and paravalvular leak of a second-time replaced mitral mechanical prosthesis, successfully treated with Amplatzer occlusion of the paravalvular leak, thus avoiding a second reoperation and improving the patient's symptoms.
MeSH terms
-
Cardiac Catheterization / instrumentation*
-
Device Removal
-
Equipment Design
-
Female
-
Heart Diseases / diagnostic imaging
-
Heart Diseases / etiology
-
Heart Diseases / surgery
-
Heart Diseases / therapy*
-
Heart Valve Prosthesis Implantation / adverse effects
-
Heart Valve Prosthesis Implantation / instrumentation*
-
Heart Valve Prosthesis*
-
Humans
-
Middle Aged
-
Mitral Valve Stenosis / diagnostic imaging
-
Mitral Valve Stenosis / surgery*
-
Prosthesis Design
-
Prosthesis Failure
-
Reoperation
-
Thrombosis / diagnostic imaging
-
Thrombosis / etiology
-
Thrombosis / surgery
-
Thrombosis / therapy*
-
Treatment Outcome
-
Ultrasonography