[Influence of fluoride ion-implanted titanium on the formation of focal adhesion plaque in vitro]

Hua Xi Kou Qiang Yi Xue Za Zhi. 2008 Apr;26(2):137-9, 143.
[Article in Chinese]

Abstract

Objective: To evaluate the chemical composition of the modified surface of fluoride ion-implanted titanium and assess the effect on the formation of focal adhesion plaque in vitro.

Methods: Pure commercial titanium discs were treated with fluoride ion implantation by plasma immersion ion implantation technique (PIII) and chemical composition and value of the surface modification layer were characterized by X-ray photoelectron spectrometer (XPS). In order to investigate the formation of focal adhesion plaque, MG-63 cells were seeded onto the surfaces of the modified Ti discs and quantified by morphometric analysis using an immunofluorescence microscope.

Results: The full range XPS spectra and fitting results indicated that the surface of fluoride ion-implanted titanium was the mixture of titanium dioxide and titanium trifluoride. Meanwhile, the quantity of focal adhesion plaque on fluoride ion-implanted titanium was more than that on the non-implanted titanium after 6 hours' cell culture.

Conclusion: The XPS data revealed that the modified surface layer of fluoride ion-implanted titanium contained titanium dioxide and titanium trifluoride, which could enhance the formation of focal adhesion plaque.

MeSH terms

  • Fluorides
  • Focal Adhesions*
  • In Vitro Techniques
  • Prostheses and Implants
  • Surface Properties*
  • Titanium

Substances

  • titanium dioxide
  • Titanium
  • Fluorides
  • titanium tetrafluoride