Cardiopulmonary exercise variables in diastolic versus systolic heart failure

Am J Cardiol. 2008 Jul 15;102(2):203-6. doi: 10.1016/j.amjcard.2008.03.041. Epub 2008 Jun 12.

Abstract

The response to cardiopulmonary exercise (CPX) in patients with heart failure (HF) with normal left ventricular (LV) ejection fractions (EFs) is not well characterized. To determine if CPX testing could distinguish between patients with HF with normal EFs (>50%; i.e., diastolic HF) and those with decreased EFs (> or =50%; i.e., systolic HF), CPX responses were compared between 185 patients with systolic HF (79% men, mean age 62.6 +/- 10.9 years) and 43 with diastolic HF (54% men, mean age 67.4 +/- 9.8 years) enrolled in a phase II multicenter clinical trial. All patients were evaluated with echocardiography and a standardized CPX test as part of the trial. CPX variables, including oxygen uptake at peak exercise (peak VO(2)) and the slope of the ventilation/carbon dioxide production ratio (VE/VCO(2)), were determined and analyzed by core laboratory personnel. Echocardiographic measurements included the LV EF, the E/A ratio, filling time, cavity volumes, right ventricular function, and mitral regurgitation. Patients in the diastolic HF group tended to be older (p <0.08), with more women (p <0.006) and with greater body mass indexes (p <0.02), than those in the systolic HF group. There was no significant difference in the use of beta blockers or the incidence of coronary artery disease. Patients with diastolic HF had decreased E/A ratios (0.9 +/- 0.4 vs 1.4 +/- 1.1, p <0.02, diastolic HF vs systolic HF) and increased filling times (30.4 +/- 3.2 vs 26.5 +/- 4.7 ms, p <0.01, diastolic HF vs systolic HF). No significant differences in peak VO(2) (14.4 +/- 1.9 vs 15.6 +/- 3.2 ml/kg/min, p = 0.06, diastolic HF vs systolic HF) were observed. The VE/VCO(2) ratios for the 2 groups were abnormal and comparable (32 2 +/- 7.5 vs 34.0 +/- 8.3, p = 0.3, diastolic HF vs systolic HF). In conclusion, the CPX response in patients with diastolic HF and systolic HF is markedly abnormal and indistinguishable with regard to peak VO(2) and ventilation despite marked differences in the LV EF.

Publication types

  • Clinical Trial
  • Clinical Trial, Phase III
  • Multicenter Study
  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Double-Blind Method
  • Exercise Test / methods*
  • Female
  • Heart Failure, Diastolic / diagnostic imaging
  • Heart Failure, Diastolic / physiopathology*
  • Heart Failure, Systolic / diagnostic imaging
  • Heart Failure, Systolic / physiopathology*
  • Heart Function Tests
  • Humans
  • Male
  • Middle Aged
  • Oxygen Consumption
  • Stroke Volume
  • Ultrasonography