Influence of natural radioactive aerosols on artificial radioactivity detection in the Spanish surveillance networks

Appl Radiat Isot. 2008 Nov;66(11):1627-31. doi: 10.1016/j.apradiso.2007.08.020. Epub 2008 Apr 11.

Abstract

The device used for continuous measurements of artificial alpha and beta activity in Spanish radiological surveillance networks is the LB BAI 9850 monitor from the Berthold Company. The temporal variation of radon decay product equilibrium introduces a varying background signal in the artificial radioactivity in these monitors. This unwanted background signal can be significantly reduced by analyzing natural radioactive aerosols and their influence on the monitor.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Aerosols / analysis*
  • Air Pollutants, Radioactive / analysis*
  • Artifacts*
  • Background Radiation*
  • Radiation Dosage
  • Radiation Monitoring / methods*
  • Radon / analysis
  • Reproducibility of Results
  • Safety Management / methods*
  • Safety Management / organization & administration*
  • Sensitivity and Specificity
  • Spain

Substances

  • Aerosols
  • Air Pollutants, Radioactive
  • Radon