A novel selective-excitation RF pulse for magnetic resonance imaging

MAGMA. 2008 May;21(3):199-205. doi: 10.1007/s10334-008-0111-9. Epub 2008 Apr 30.

Abstract

Object: A selective-excitation radiofrequency (RF) pulse that uses hard pulses composed of a sequence of composite pulses with positive and negative phases (P/N pulse) is proposed herein. Because the amplitude of the RF signal is unchanged during the excitation, RF amplification can be accomplished using a nonlinear RF power amplifier (i.e., class C or D type).

Materials and methods: In this article, Fourier series have been first used to analyze the equivalence between the proposed P/N pulse and the conventional soft pulse on selective excitation. Subsequently, computer simulations based on density-matrix theory are used to compare the excitation profiles of both the soft and the P/N pulses.

Results: The excitation profiles of the P/N pulses have been measured experimentally through a home-built 0.3-T magnetic resonance imaging (MRI) system. In addition, several slices of images have been obtained as proofs by using the multislice two-dimensional spin echo sequence through replacement of the conventional soft pulse by the proposed P/N pulse.

Conclusion: Because the perfect selectivity of the proposed P/N pulse, it can be used for imaging studies to improve the efficiency of amplification at the lowest cost.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Brain / anatomy & histology*
  • Computer Simulation
  • Fourier Analysis*
  • Humans
  • Magnetic Resonance Imaging / methods