Stent placement for failed angioplasty of aortic stenoses: report of two cases

Cardiovasc Intervent Radiol. 1991 Sep-Oct;14(5):316-9. doi: 10.1007/BF02578459.

Abstract

In 2 patients, an aortic stenosis failed to respond adequately to balloon dilatation but was successfully treated by implantation of a self-expandable large caliber endoprosthesis and subsequent balloon angioplasty. Intravascular ultrasound helped to classify the characteristics of the lesion in preparation for intervention.

Publication types

  • Case Reports

MeSH terms

  • Angiography, Digital Subtraction
  • Angioplasty, Balloon*
  • Aorta, Abdominal
  • Aortic Diseases / diagnosis
  • Aortic Diseases / therapy*
  • Arteriosclerosis / diagnosis
  • Arteriosclerosis / therapy*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Stents*
  • Ultrasonography / methods