Gray-scale median of the atherosclerotic plaque can predict success of lumen re-entry during subintimal femoral-popliteal angioplasty

J Vasc Surg. 2008 Jan;47(1):109-15; discussion 115-6. doi: 10.1016/j.jvs.2007.09.039.

Abstract

Objective: This study assessed whether the duplex ultrasound (DUS)-derived gray-scale median (GSM) of the most six distal portion of the occluded femoral-popliteal arterial segment can predict success of lumen re-entry for subintimal angioplasty.

Methods: During the last 3 years, 108 patients (62% men) with a mean age of 73 +/- 10 years underwent 116 primary attempted DUS-guided subintimal angioplasties of the femoral-popliteal segment. Preprocedural B-mode DUS images of the plaque at the most distal occlusion segment were digitalized and normalized using Photoshop (Adobe, San Jose, Calif) software and standard criteria (gray level, 0 to 5 for lumen blood and 185 to 190 for the adventitia on a linear scale of 0 to 255). Overall GSM of the plaque segment about 2 cm long, immediately before the planned re-entry point to the true arterial lumen, was used for retrospective correlation with procedure success and other clinical indicators.

Results: Mean plaque GSM for all cases was 22.5 +/- 12.6 (range, 3 to 60). The overall success rate of subintimal angioplasty procedures was 85%. Mean plaque GSM for 99 successful cases (18.4 +/- 7.8) was significantly lower than for 17 cases (46.4 +/- 8.1) where we failed (P < .0001). We failed in 90% of 19 cases with GSM >35, in 71% of 24 cases with GSM >20, and in 50% of 34 cases with GSM >25. There was no statistically significant difference (P = .45) between plaque GSM in 64 patients with diabetes (23.3 +/- 13.5) compared with 52 nondiabetic patients (21.5 +/- 11.4). Similarly, plaque GSM was not statistically different (P = .9) in 52 patients with renal insufficiency (22.7 +/- 13.2) compared with 64 patients with normal creatinine levels (22.4 +/- 12.2). At the 6-month follow-up, no statistically significant difference was found between mean GSM (17.8 +/- 7.8) in 47 stenosis-free cases compared with mean GSM (18 +/- 6.8) in 22 cases where severe restenosis (>70%) or reocclusion was identified by DUS scan (P = .4).

Conclusions: Plaque echogenicity represented by DUS-derived GSM can be used to predict the success of primary subintimal femoral-popliteal angioplasties.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Angioplasty* / adverse effects
  • Angioplasty* / methods
  • Atherosclerosis / diagnostic imaging*
  • Atherosclerosis / physiopathology
  • Atherosclerosis / surgery
  • Female
  • Femoral Artery / diagnostic imaging*
  • Femoral Artery / physiopathology
  • Femoral Artery / surgery
  • Humans
  • Image Interpretation, Computer-Assisted
  • Male
  • Middle Aged
  • Popliteal Artery / diagnostic imaging*
  • Popliteal Artery / physiopathology
  • Popliteal Artery / surgery
  • Predictive Value of Tests
  • Retrospective Studies
  • Time Factors
  • Treatment Outcome
  • Ultrasonography, Doppler, Duplex*
  • Ultrasonography, Interventional*
  • Vascular Patency