An a posteriori method based on photo-acoustic cell information to correct for lidar transmitter spectral shift: application to atmospheric CO(2) differential absorption lidar measurements

Appl Spectrosc. 2007 Oct;61(10):1068-75. doi: 10.1366/000370207782217798.

Abstract

An a posteriori corrective method based on photo-acoustic cell (PAC) information is proposed to correct for laser transmitter spectral shift during atmospheric CO(2) measurements by 2 microm heterodyne differential absorption lidar (HDIAL) technique. The method for using the PAC signal to retrieve the actual atmospheric CO(2) absorption is presented in detail. This issue is tackled using a weighting function. The performance of the proposed corrective method is discussed and the various sources of error associated with the PAC signal are investigated. For 300 shots averaged and a frequency shift (from the CO(2) absorption line center) lower than the CO(2) absorption line half-width, the relative error on HDIAL CO(2) mixing ratio measurements is lower than 1.3%. The corrective method is validated in absolute value by comparison between HDIAL and in situ sensor measurements of CO(2).