Tricuspid valve annuloplasty with a flexible prosthetic band

Interact Cardiovasc Thorac Surg. 2007 Dec;6(6):731-5. doi: 10.1510/icvts.2007.156786. Epub 2007 Aug 31.

Abstract

This study evaluates the application to the tricuspid valve of a flexible prosthetic band originally devised for mitral repair. Between March 2001 and May 2005, 53 consecutive patients (age 66.2+/-8.5 years) with significant tricuspid regurgitation and dilatation of the right-sided cardiac chambers underwent tricuspid valve annuloplasty with the band and concomitant mitral repair or replacement. Thirty-one patients (58.5%) were in NYHA class III or IV, and 33 (62.3%) had a history of right heart failure. Follow-up was 19.2+/-14.0 months. Three patients (5.7%) died before discharge, and one during follow-up. One late reoperation was required for mitral endocarditis. NYHA class decreased in survivors from 2.7+/-0.8 to 1.4+/-0.6 (P<0.0001), and the symptoms of right heart failure improved significantly after surgery. Tricuspid regurgitation was mild or absent in 44 survivors (89.8%) and moderate in 5 (10.2%). Regurgitation significantly decreased even in patients with risk factors for tricuspid repair failure or with persistent left ventricular dysfunction. The 4-year actuarial freedom from tricuspid regurgitation grade >1 was 88.7%. By univariable analysis, preoperative tricuspid regurgitation grade >2, right ventricular shortening fraction <35%, and permanent pacemaker were associated with the risk of recurrent moderate regurgitation, though only probably so (P=0.077, 0.061, and 0.097, respectively).

Publication types

  • Evaluation Study

MeSH terms

  • Aged
  • Female
  • Follow-Up Studies
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis*
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Mitral Valve / diagnostic imaging
  • Mitral Valve / surgery*
  • Mitral Valve Insufficiency / complications*
  • Mitral Valve Insufficiency / diagnostic imaging
  • Mitral Valve Insufficiency / mortality
  • Mitral Valve Insufficiency / surgery
  • Mitral Valve Stenosis / complications*
  • Mitral Valve Stenosis / diagnostic imaging
  • Mitral Valve Stenosis / mortality
  • Mitral Valve Stenosis / surgery
  • Pliability
  • Prosthesis Design
  • Recurrence
  • Severity of Illness Index
  • Time Factors
  • Treatment Outcome
  • Tricuspid Valve / diagnostic imaging
  • Tricuspid Valve / surgery*
  • Tricuspid Valve Insufficiency / diagnostic imaging
  • Tricuspid Valve Insufficiency / etiology
  • Tricuspid Valve Insufficiency / mortality
  • Tricuspid Valve Insufficiency / surgery*
  • Ultrasonography