Attenuation-corrected vs. nonattenuation-corrected 2-deoxy-2-[F-18]fluoro-D-glucose-positron emission tomography in oncology: a systematic review

Mol Imaging Biol. 2007 May-Jun;9(3):99-105. doi: 10.1007/s11307-007-0076-5.

Abstract

Purpose: To perform a systematic review and meta-analysis to determine the diagnostic accuracy of attenuation-corrected (AC) vs. nonattenuation-corrected (NAC) 2-deoxy-2-[F-18]fluoro-D-glucose-positron emission tomography (FDG-PET) in oncological patients.

Procedures: Following a comprehensive search of the literature, two reviewers independently assessed the methodological quality of eligible studies. The diagnostic value of AC was studied through its sensitivity/specificity compared to histology, and by comparing the relative lesion detection rate reported with NAC-PET vs. AC, for full-ring and dual-head coincidence PET (FR- and DH-PET, respectively).

Results: Twelve studies were included. For FR-PET, the pooled sensitivity/specificity on a patient basis was 64/97% for AC and 62/99% for NAC, respectively. Pooled lesion detection with NAC vs. AC was 98% [95% confidence interval (95% CI): 96-99%, n = 1,012 lesions] for FR-PET, and 88% (95% CI:81-94%, n = 288 lesions) for DH-PET.

Conclusions: Findings suggest similar sensitivity/specificity and lesion detection for NAC vs. AC FR-PET and significantly higher lesion detection for NAC vs. AC DH-PET.

Publication types

  • Comparative Study
  • Review
  • Systematic Review

MeSH terms

  • Fluorodeoxyglucose F18*
  • Humans
  • Neoplasms / diagnostic imaging*
  • Neoplasms / pathology
  • Positron-Emission Tomography / methods*
  • Positron-Emission Tomography / statistics & numerical data
  • Radiopharmaceuticals*
  • Sensitivity and Specificity

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18