Oxyanion flux characterization using passive flux meters: development and field testing of surfactant-modified granular activated carbon

J Contam Hydrol. 2007 Jul 17;92(3-4):208-29. doi: 10.1016/j.jconhyd.2006.12.002. Epub 2007 Jan 11.

Abstract

We report here on the extension of Passive Flux Meter (PFM) applications for measuring fluxes of oxyanions in groundwater, and present results for laboratory and field studies. Granular activated carbon, with and without impregnated silver (GAC and SI-GAC, respectively), was modified with a cationic surfactant, hexadecyltrimethylammonium (HDTMA), to enhance the anion exchange capacity (AEC). Langmuir isotherm sorption maxima for oxyanions measured in batch experiments were in the following order: perchlorate>>chromate>selenate, consistent with their selectivity. Linear sorption isotherms for several alcohols suggest that surfactant modification of GAC and SI-GAC reduced (approximately 30-45%) sorption of alcohols by GAC. Water and oxyanion fluxes (perchlorate and chromate) measured by deploying PFMs packed with surfactant-modified GAC (SM-GAC) or surfactant-modified, silver-impregnated GAC (SM-SI-GAC) in laboratory flow chambers were in close agreement with the imposed fluxes. The use of SM-SI-GAC as a PFM sorbent was evaluated at a field site with perchlorate contamination of a shallow unconfined aquifer. PFMs packed with SM-SI-GAC were deployed in three existing monitoring wells with a perchlorate concentration range of approximately 2.5 to 190 mg/L. PFM-measured, depth-averaged, groundwater fluxes ranged from 1.8 to 7.6 cm/day, while depth-averaged perchlorate fluxes varied from 0.22 to 1.7 g/m2/day. Groundwater and perchlorate flux distributions measured in two PFM deployments closely matched each other. Depth-averaged Darcy fluxes measured with PFMs were in line with an estimate from a borehole dilution test, but much smaller than those based on hydraulic conductivity and head gradients; this is likely due to flow divergence caused by well-screen clogging. Flux-averaged perchlorate concentrations measured with PFM deployments matched concentrations in groundwater samples taken from one well, but not in two other wells, pointing to the need for additional field testing. Use of the surfactant-modified GACs for measuring fluxes of other anions of environmental interest is discussed.

Publication types

  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Adsorption
  • Anions / analysis
  • Anions / chemistry*
  • Charcoal / analysis
  • Charcoal / chemistry
  • Chromates / analysis
  • Chromates / chemistry
  • Environmental Monitoring / methods*
  • Kinetics
  • Oxygen / chemistry
  • Perchlorates / analysis
  • Perchlorates / chemistry
  • Selenic Acid
  • Selenium Compounds / analysis
  • Selenium Compounds / chemistry
  • Water Pollutants, Chemical / analysis*
  • Water Pollutants, Chemical / chemistry
  • Water Pollution / analysis*
  • Water Pollution / prevention & control

Substances

  • Anions
  • Chromates
  • Perchlorates
  • Selenium Compounds
  • Water Pollutants, Chemical
  • Charcoal
  • Selenic Acid
  • Oxygen
  • perchlorate