Background: Increasing reports suggest that endoscopic removal of benign ampullary and duodenal polyps is safe and frequently definitive; however, most reported polyps have been small in size (<3 cm). We have developed experience with endoscopic removal of increasingly large and complex polyps.
Patients: Fifty-one cases of endoscopic removal were attempted and grouped according to size: group A (n = 22) polyps 1 to 3 cm and group B (n = 29) polyps 3 cm or larger, including 7 cases larger than 5 cm. When the ampulla was involved, biductal sphincterotomy and prophylactic pancreatic duct stent placement was performed first, followed by saline solution-assisted piecemeal polypectomy, argon plasma coagulation, selective endoclip placement, and recovery of all polyp fragments.
Interventions: Endoscopic removal of duodenal and ampullary adenomas.
Results: The outcomes of small and large adenoma removal include mean number of endoscopic retrograde cholangiopancreatographies required for complete removal (2.09 vs 2.56, P = .392), number of complications (4.5% vs 13.9%, P = .375), discovery of unsuspected cancer (0% vs 10.3%, P = .242), and final definitive resolution (100% vs 86.2%, P = .124). Complete removal was achieved in 92.2% of all patients.
Limitations: This was a single center retrospective study.
Conclusions: Large (>/=3 cm) ampullary and duodenal polyps comprised 56.9% of our endoscopically treated cases and present special challenges to definitive endoscopic removal. Successful removal of even very large sessile lesions is possible with minimal increase in risk.