Quantitative reconstruction of refractive index distribution and imaging of glucose concentration by using diffusing light

Appl Opt. 2006 Nov 10;45(32):8360-5. doi: 10.1364/ao.45.008360.

Abstract

We show that a two-step reconstruction method can be adapted to improve the quantitative accuracy of the refractive index reconstruction in phase-contrast diffuse optical tomography (PCDOT). We also describe the possibility of imaging tissue glucose concentration with PCDOT. In this two-step method, we first use our existing finite-element reconstruction algorithm to recover the position and shape of a target. We then use the position and size of the target as a priori information to reconstruct a single value of the refractive index within the target and background regions using a region reconstruction method. Due to the extremely low contrast available in the refractive index reconstruction, we incorporate a data normalization scheme into the two-step reconstruction to combat the associated low signal-to-noise ratio. Through a series of phantom experiments we find that this two-step reconstruction method can considerably improve the quantitative accuracy of the refractive index reconstruction. The results show that the relative error of the reconstructed refractive index is reduced from 20% to within 1.5%. We also demonstrate the possibility of PCDOT for recovering glucose concentration using these phantom experiments.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Algorithms*
  • Biosensing Techniques / methods*
  • Computer Simulation
  • Glucose / analysis*
  • Image Interpretation, Computer-Assisted / methods*
  • Light
  • Models, Biological*
  • Refractometry / methods*
  • Scattering, Radiation

Substances

  • Glucose