Cardiac functional analysis by free-breath real-time cine CMR with a spatiotemporal filtering method, TSENSE: comparison with breath-hold cine CMR

J Cardiovasc Magn Reson. 2006;8(6):801-7. doi: 10.1080/10976640600777686.

Abstract

The aim of this study was to assess the accuracy of cardiac functional values obtained from free-breathing real-time cine CMR with the temporal sensitivity encoding (TSENSE) technique by comparing them with values obtained from conventional cine CMR. For the real-time cine CMR, two protocols were employed, one with good temporal resolution and one with good spatial resolution. The functional values obtained from the high temporal resolution real-time cine CMR agreed and correlated well with those of cine CMR. On the other hand, statistically significant but clinically slight overestimation of ESV (p < .05) and underestimation of EF (p < .01) were observed with the other protocol. Real-time cine CMR with TSENSE can provide acceptable cardiac functional values.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Diastole
  • Female
  • Heart Diseases / diagnosis
  • Heart Ventricles / pathology*
  • Humans
  • Magnetic Resonance Imaging, Cine / methods*
  • Male
  • Middle Aged
  • Respiration
  • Stroke Volume
  • Systole
  • Ventricular Function, Left*