Two-dimensional microcolumn separation platform for proteomics consisting of on-line coupled capillary isoelectric focusing and capillary electrochromatography. 1. Evaluation of the capillary-based two-dimensional platform with proteins, peptides, and human serum

J Proteome Res. 2006 Aug;5(8):2001-8. doi: 10.1021/pr060185u.

Abstract

In this report, an on-line coupling of capillary isoelectric focusing (CIEF) to capillary electrochromatography (CEC) is developed via a nanoinjector valve for performing two-dimensional (2D) proteomics separation. CIEF constitutes the first separation dimension, while CEC operates as the second separation dimension. Besides the orthogonal migration mechanisms of the two capillary-based separation modes, which lead to a 2D system whose overall peak capacity is the product of the peak capacity of the individual modes, the solvent of the CIEF mode is a weak eluent for the reversed-phase CEC (RP-CEC) mode, thus, allowing the transferring of focused fractions from CIEF to CEC without inducing band broadening, and instead zone sharpening would result. In fact, the transferred focused protein fraction from the CIEF column to the CEC column will stay tightly adsorbed to the inlet top of the CEC column until it will be eluted and separated into its protein components with a hydro-organic mobile phase. The theoretical peak capacity of the CIEF-CEC 2D platform is estimated at n(CIEF) (= 560) x n(CEC) (= 97) = 54 320. This peak capacity is more than needed for proteomics profiling. Also, only a fraction of this peak capacity is needed when looking at heart cuts for performing subproteomics. The 2D platform described here offers the convenience to generate the needed peak capacity to solve a given proteomic separation problem. This is facilitated by the RP-CEC dimension, which ensures rapid isocratic separation of proteins and peptides and rapid solvent change and column equilibration and avoids lengthy gradient elution. The RP-CEC column is based on neutral C17 monolith, which offers high separation efficiency and relatively high column permeability. To the best of our knowledge, the proposed 2D platform combining CIEF and CEC is reported for the first time for proteins and proteomics.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Amino Acid Sequence
  • Capillary Electrochromatography* / instrumentation
  • Capillary Electrochromatography* / methods
  • Humans
  • Isoelectric Focusing* / instrumentation
  • Isoelectric Focusing* / methods
  • Molecular Sequence Data
  • Peptides / analysis*
  • Peptides / genetics
  • Proteins / analysis*
  • Proteins / genetics
  • Proteomics / methods*
  • Serum Albumin / chemistry

Substances

  • Peptides
  • Proteins
  • Serum Albumin