[Comparison of mini-probe endoscopic ultrasonography with computed tomography in preoperative staging of esophageal cancer]

Zhonghua Zhong Liu Za Zhi. 2006 Feb;28(2):123-6.
[Article in Chinese]

Abstract

Objective: To compare mini-probe endoscopic ultrasonography (MCUS) with computed tomography (CT) in preoperative T and N staging of esophageal cancer, and to find out the MCUS parameters to judge lymph node metastasis for esophageal cancer.

Methods: Thirty-five patients received both MCUS and CT preoperatively, on both of which the T and N stages were determined. The accuracy, sensitivity, specificity, positive predicting value and negative predicting value were compared with the postoperative pathological results.

Results: The accuracy of MCUS was 85.7% in T staging and 85.7% and 80.0% in N staging by the two different methods, which were 45.7% and 74.3%, respectively, by CT.

Conclusion: MCUS is better than CT in preoperative staging for esophageal cancer. The ratio of short to long axis (S/L) combined with short axis is a useful way to determine lymph node metastasis.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Double-Blind Method
  • Endosonography* / instrumentation
  • Endosonography* / methods
  • Esophageal Neoplasms / diagnostic imaging*
  • Esophageal Neoplasms / pathology
  • Esophageal Neoplasms / surgery
  • Esophagus / diagnostic imaging
  • Female
  • Humans
  • Lymph Nodes / diagnostic imaging
  • Lymph Nodes / pathology*
  • Lymphatic Metastasis
  • Male
  • Middle Aged
  • Neoplasm Staging / methods*
  • Preoperative Care
  • Tomography, X-Ray Computed