[Utilizing fereducer reaction to enhance DC corona radical shower for benzene treatment]

Huan Jing Ke Xue. 2005 Nov;26(6):24-7.
[Article in Chinese]

Abstract

Fereducer reaction is introduced to enhance DC corona radicals shower for removal of benzene in air. In the presence of nozzle electrode gas containing Fereducer reagent, the enhanced decomposing efficiencies were 21% and 4.2% for benzene concentration of 953 mg/m3 and 63 mg/m3, respectively. The enhancement of benzene removal was remarkable in the presence of nozzle electrode gas (O2, H2O) with the highest removal rate of 89.6%. Lower initial concentration of benzene has higher removal efficiency. However, higher absolute removal rate would be achieved when initial concentration of benzene was higher.

Publication types

  • English Abstract
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Air Pollutants / chemistry*
  • Air Pollution / prevention & control*
  • Benzene / chemistry*
  • Electrochemistry
  • Electrodes*
  • Free Radicals
  • Gases / chemistry

Substances

  • Air Pollutants
  • Free Radicals
  • Gases
  • Benzene