The impact of heterogeneity correction on dosimetric parameters that predict for radiation pneumonitis

Int J Radiat Oncol Biol Phys. 2006 May 1;65(1):125-31. doi: 10.1016/j.ijrobp.2005.09.047. Epub 2006 Jan 19.

Abstract

Purpose: To determine if heterogeneity correction significantly affects commonly measured dosimetric parameters predicting pulmonary toxicity in patients receiving radiation for lung cancer.

Methods and materials: Sixty-eight patients treated for lung cancer were evaluated. The conformal treatment technique mostly employed anteroposterior/posterior-anterior fields and off-cord obliques. The percent total lung volume receiving 20 Gy or higher (V20) and mean lung dose (MLD) were correlated with the incidence of radiation pneumonitis. Parameters from both heterogeneity-corrected and heterogeneity-uncorrected plans were used to assess this risk.

Results: Univariate analysis revealed a significant correlation between the development of radiation pneumonitis and both V20 and MLD. A best-fit line to a plot of V20 from the homogeneous plan against the corresponding V20 heterogeneous value produced a slope of 1.00 and zero offset, indicating no difference between the two parameters. For MLD, a similarly significant correlation is seen between the heterogeneous and homogeneous parameters, indicating a 4% difference when correcting for heterogeneity. A significant correlation was also observed between the MLD and V20 parameters (p < 0.0001).

Conclusions: A high degree of correlation exists between heterogeneity-corrected and heterogeneity-uncorrected dosimetric parameters for lung and the risk of developing pneumonitis. Either V20 or MLD predicts the pneumonitis risk with similar effect.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Analysis of Variance
  • Female
  • Humans
  • Lung / radiation effects*
  • Lung Neoplasms / radiotherapy*
  • Male
  • Middle Aged
  • Radiation Pneumonitis / etiology*
  • Radiation Tolerance
  • Radiotherapy Dosage
  • Radiotherapy, Conformal