Hydroxyapatite chromatography of phage-display virions

Biotechniques. 2005 Dec;39(6):879-84. doi: 10.2144/000112032.

Abstract

Hydroxyapatite column chromatography can be used to purify filamentous bacteriophage--the phage most commonly used for phage display. Virions that have been partially purified from culture supernatant by two cycles of precipitation in 2% polyethylene glycol are adsorbed onto the matrix at a density of at least 7.6 x 10(13) virions (about 3 mg) per milliliter of packed bed volume in phosphate-buffered saline (PBS; 0.15 M NaCl, 5 mM NaH2PO4, pH-adjusted to 7.0 with NaOH). The matrix is washed successively with wash buffer I(150 mM NaCl, 125 mM phosphate, pH 7.0), wash buffer II (2.55 M NaCl, 125 mM phosphate, pH 7.0), and wash buffer I; after which virions are desorbed in desorption buffer (150 mM NaCl, 200 mM phosphate, pH 7.0), and the matrix is stripped with stripping buffer (150 mM NaCl, 1 Mphosphate, pH 7.0). About half of the applied virions are recovered in desorption buffer. Western blot analysis shows that they have undetectable levels of host-derived protein contaminants that are present in the input virions and in virions purified by CsCl equilibrium density gradient centrifugation--the method most commonly used to prepare virions in high purity. Hydroxyapatite chromatography is thus an attractive alternative method for purifying filamentous virions, particularly when the scale is too large for ultracentrifugation to be practical.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Bacteriophages / isolation & purification*
  • Blotting, Western
  • Chromatography / methods*
  • Durapatite*
  • Virion / isolation & purification*

Substances

  • Durapatite