The HLDA8 blind panel: findings and conclusions

J Immunol Methods. 2005 Oct 20;305(1):75-83. doi: 10.1016/j.jim.2005.07.003. Epub 2005 Aug 15.

Abstract

There were over 600 antibodies submitted to HLDA8, with many of unknown specificity. Of these, 101 antibodies were selected for a blind panel study that also included 5 negative controls and 27 positive controls of known CD specificity making a total of 133 antibodies in the final panel. Of the 101 unknowns, 31 antibodies were identified during the course of this blind panel study as being specific for known molecules and included some specific for MHC class II antigens, CD45 isoforms and the Dombrock antigen. Several antibody pairs among those in the blind panel were found to have very similar staining patterns and were therefore compared by immunohistochemical and/or Western blot analyses for identity.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Antibodies / immunology*
  • Antibody Specificity / immunology*
  • Antigens, CD / analysis*
  • Antigens, Surface / analysis*
  • Blotting, Western
  • Cell Line
  • Humans
  • Immunochemistry

Substances

  • Antibodies
  • Antigens, CD
  • Antigens, Surface