[Advantage of using echography for optic nerve head estimation of glaucoma patients]

Klin Oczna. 2005;107(4-6):289-91.
[Article in Polish]

Abstract

Purpose: To evaluate the possibility and advantages of using echography for optic nerve head estimation of glaucoma patients.

Material and methods: 146 patients (146 eyes) - group A and 20 glaucoma patients (24 eyes)- group B underwent ultrasound investigation. On B - scan the optic nerve head was evaluated with the help of 10 MHz probe. In the patients with the possibility of glaucoma with transparent ocular media the C/D ratio was measured.

Results: In 6 patients of group A large cup of the optic disc was detected, which correlated with the eye fundus picture. In group B only in one case there was no correlation between echographic image of the optic cup and the eye fundus picture.

Conclusions: During the ultrasound investigation of the eyes of patients before cataract extraction, corneal transplantation or vitreoretinal surgery we suggest the echography imaging of the optic cup as a routine procedure, which will be helpful in the diagnosis and treatment of glaucoma.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Female
  • Glaucoma / diagnostic imaging*
  • Humans
  • Male
  • Middle Aged
  • Optic Nerve / diagnostic imaging*
  • Predictive Value of Tests
  • Sensitivity and Specificity
  • Ultrasonography